Refine your search |
|
CMC AREA |
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
cadmium |
0.5
to 2.0
|
0.4
to 2.8
|
0.5
to 2.0
|
0.45
to 4.0
|
Mechanism(s) for measurement service delivery:
DMR-8, DMR-342, DMR-400, DMR-171: annual PT and value-assignment through MRTC program
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-009
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
cadmium |
950
to 1050
|
0.30
to 0.40
|
950
to 1050
|
0.2
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-85, DMR-461
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-006
|