Your query 'cenam' produced 14 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Mass and related quantities for Mexico (.PDF file)
Force: tension and compression. Force measuring device, 50 N to 500 N
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 500 N to 1000 N
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 1 kN to 3 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 2.5 kN to 5 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 5 kN to 10 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 10 kN to 20 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 20 kN to 50 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 50 kN to 110 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 110 kN to 150 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 0.00002
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H004-001 and 002
 
Force: tension and compression. Force measuring device, 150 kN to 200 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 4.7E-04
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H005-001 and 002
 
Force: tension and compression. Force measuring device, 200 kN to 500 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 4.7E-04
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H005-001 and 002
 
Force: tension and compression. Force measuring device, 500 kN to 1000 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 9.5E-04
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H005-003 and 004
 
Force: tension and compression. Force measuring device, 1000 kN to 1500 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 7.0E-04
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H005-003 and 004
 
Force: tension and compression. Force measuring device, 1500 kN to 2000 kN
Relative expanded uncertainty (k = 2, level of confidence 95%): 7.0E-04
Direct comparison
Temperature: (22 ± 1) °C
Internal NMI service identifier: CENAM/720-H005-003 and 004