Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (8)
PHYSICS
Photometry (8)
Illuminance (4)
Luminous intensity (3)
Illuminance responsivity, tungsten source (1)
GEOGRAPHIC LOCATION
COOMET (8)
Belarus (8)
Result of the search
Your query 'Belarus' produced 8 results New search

 
Belarus, BelGIM (Belarussian State Institute for Metrology)
Complete CMCs in Photometry and Radiometry for Belarus (.PDF file)
Luminous intensity. Tungsten lamp, 5 cd to 35 cd
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.5 to 0.8
Photometric bench and reference lamps/photometer
Correlated colour temperature: 2000 K to 3200 K
The expanded uncertainty varies with measurand. Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1001
 
Luminous intensity. Tungsten lamp, 35 cd to 500 cd
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Photometric bench and reference lamps/photometer
Correlated colour temperature: 2360 K to 2900 K
Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1001
 
Luminous intensity. Tungsten lamp, 500 cd to 1500 cd
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8 to 1.5
Photometric bench and reference lamps/photometer
Correlated colour temperature: 2800 K to 2900 K
The expanded uncertainty varies with measurand. Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1001
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Photometric bench and reference lamps
Illuminance: 100 lx to 500 lx
Correlated colour temperature: 2856 K
Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1003
 
Illuminance. Tungsten lamp, 1 lx to 5 lx
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2.0 to 1.5
Photometric bench and reference lamps/photometer
Correlated colour temperature: 2000 K to 3200 K
The expanded uncertainty varies with measurand. Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1005
 
Illuminance. Tungsten lamp, 5 lx to 35 lx
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.5 to 0.8
Photometric bench and photometer
Correlated colour temperature: 2000 K to 3200 K
The expanded uncertainty varies with measurand. Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1006
 
Illuminance. Tungsten lamp, 35 lx to 500 lx
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Photometric bench and photometer
Correlated colour temperature: 2360 K to 2900 K
Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1006
 
Illuminance. Tungsten lamp, 500 lx to 2000 lx
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8 to 1.5
Photometric bench and photometer
Correlated colour temperature: 2800 K to 2900 K
The expanded uncertainty varies with measurand. Other kind of sources can be measured with larger uncertainty
Approved on 01 April 2016
Internal NMI service identifier: COO-PR-BELGIM-1006