Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (4)
PHYSICS
Mass, mass standards
DC voltage, current, and resistance (4)
DC voltage sources: intermediate values (higher than 10 V to 1100 V) (4)
CHEMICAL ANALYTE
carbon monoxide
GEOGRAPHIC LOCATION
APMP (4)
Thailand (4)
Result of the search
Your query 'NIMT' produced 4 results New search

 
Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, voltage V, > 10 V to 100 V
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.5 v + 15), v in V
Compare against DC standard
Internal NMI service identifier: NIMT/8
 
DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, voltage V, > 100 V to 1000 V
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.8 v + 200), v in V
Compare against DC standard
Internal NMI service identifier: NIMT/9
 
DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, 100 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.5
Compare against DC standard
Internal NMI service identifier: NIMT/5
 
DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.7
Compare against DC standard
Internal NMI service identifier: NIMT/6