| | | Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas) | |  | Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
|  | |
| AC current, AC current up to 100 A, meters. AC ammeter, multimeter, multifunction calibrator, 0.0001 A to 11 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 113 to 5849 | | Direct comparison | | Frequency: 10 Hz to 10 kHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/62201 | | Uncertainty table |
| | | AC power, AC power and energy, single phase (frequencies below or equal to 400 Hz). Watthour meter, wattmeter, 15 W to 12000 W | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 289 | | Comparison | | Frequency: 60 Hz | | Applied voltage: 120 V and 240 V | | Current: (0.25 A at 120 V and 0.3 A at 240 V) to 50 A | | Power factor: 1, 0.5 lead, 0.5 lag | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/71101 |
| | | Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia) | |  | Complete CMCs in Mass and related quantities for Costa Rica (.PDF file)
|  | |
| Conventional mass. Mass standards, 1 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 2 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 5 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 10 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 20 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 50 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.004 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 100 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.005 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 200 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.007 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 500 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.008 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 1 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.010 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 2 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.013 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 5 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.017 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 10 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.020 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 20 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.027 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 50 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.033 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 100 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.053 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 200 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.10 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 500 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.27 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
|