Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry
CMCs General Physics (2)
PHYSICS
Fluid flow
DC voltage, current, and resistance
AC voltage, current, and power (2)
AC power and energy: single phase (frequency <= 400 Hz, active power) (2)
GEOGRAPHIC LOCATION
SIM (2)
Mexico (2)
Result of the search
Your query 'cenam' produced 2 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
AC power and energy: single phase (frequency <= 400 Hz, active power). Multifunction calibrators, 60 W to 2.4E+03 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 100
Direct comparison
Voltage: 120 V, 240 V
Current: 1 A, 10 A
Power factor: 1 to 0.5, inductive or capactive
Frequency: 60 Hz
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001B-CC
 
AC power and energy: single phase (frequency <= 400 Hz, active power). Power meter, 0 W to 6E+04 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-01
Uncertainty table