Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (35)
PHYSICS
AC voltage, current, and power (35)
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V) (35)
GEOGRAPHIC LOCATION
APMP (35)
Thailand (35)
Result of the search
Your query 'NIMT' produced 35 results New search
1  2

 
Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 106
AC-DC voltage transfer
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/60
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 85
AC-DC voltage transfer
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/61
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 81
AC-DC voltage transfer
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/62
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 81
AC-DC voltage transfer
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/63
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 100
AC-DC voltage transfer
Frequency: 100 kHz
Internal NMI service identifier: NIMT/64
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 150
AC-DC voltage transfer
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/65
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 10 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 250
AC-DC voltage transfer
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/66
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 76
AC-DC voltage transfer
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/67
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 61
AC-DC voltage transfer
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/68
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 61
AC-DC voltage transfer
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/69
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 61
AC-DC voltage transfer
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/70
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 71
AC-DC voltage transfer
Frequency: 100 kHz
Internal NMI service identifier: NIMT/71
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 140
AC-DC voltage transfer
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/72
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 200
AC-DC voltage transfer
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/73
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 66
AC-DC voltage transfer
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/74
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47
AC-DC voltage transfer
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/75
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47
AC-DC voltage transfer
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/76
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47
AC-DC voltage transfer
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/77
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 52
AC-DC voltage transfer
Frequency: 100 kHz
Internal NMI service identifier: NIMT/78
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 100
AC-DC voltage transfer
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/79