Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'cenam' produced 580 results
|
New search
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
2-pentanol
|
2-pentanol |
98
to 100
|
0.3
to 1
|
99.76
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR 174b
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-015
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
calcium carbonate
|
total iron as iron (III) oxide |
1.3
to 1.7
|
0.1
|
1.51
|
0.06
|
Mechanism(s) for measurement service delivery:
DMR 59a
Internal NMI service identifier: CENAM/610-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
copper alloy
|
tin |
0.03
to 0.3
|
7
to 3
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 19 July 2010. Uncertainty convention 2.
Internal NMI service identifier: CENAM/620-Q008-20
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
phenanthrene |
3
to 15
|
3
to 1
|
8.06
to 103.1
|
0.16
to 1.9
|
Mechanism(s) for measurement service delivery:
DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2.78, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
copper |
950
to 1050
|
0.15
to 0.5
|
999.1
|
0.2
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR 17, CAL-620-51
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q014-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
calcium carbonate
|
total titanium as titanium (IV) oxide |
100
to 1050
|
10
to 40
|
140
to 910
|
10
to 40
|
Mechanism(s) for measurement service delivery:
DMR 59a, DMR 64a
Uncertainty convention 1.
Internal NMI service identifier: CENAM/610-009
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
glucose
|
glucose |
98
to 100
|
0.1
to 0.6
|
99.01
|
0.14
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-50, DMR-51, DMR 190a
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-016
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
nickel |
950
to 1050
|
0.40
to 0.6
|
950
to 1050
|
0.5
to 0.7
|
Mechanism(s) for measurement service delivery:
DMR-40, DMR-465
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q014-002
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
fluoranthene |
3
to 15
|
3
to 1
|
6.670
to 102.0
|
0.077
to 2.1
|
Mechanism(s) for measurement service delivery:
DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-002
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
calcium |
950
to 1050
|
0.15
to 0.40
|
950
to 1050
|
0.2
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-55
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q014-003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
benzo(a)pyrene |
3
to 15
|
3
to 1
|
6.270
to 97.1
|
0.079
to 1.2
|
Mechanism(s) for measurement service delivery:
DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
sucrose
|
sucrose |
98
to 100
|
0.1
to 0.6
|
99.46
|
0.17
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR 81a
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-017
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
fructose
|
fructose |
98
to 100
|
0.1
to 0.6
|
99.76
|
0.2
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-50, DMR-51
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-018
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
benzo(ghi)perylene |
3
to 15
|
3
to 1
|
12.34
to 66.1
|
0.18
to 1.4
|
Mechanism(s) for measurement service delivery:
DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
sediment
|
PCB 153 |
20
to 620
|
16
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services, Proficiency test service: PT 630-IL-1203
Uncertainty convention 2. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-011
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
sodium |
950
to 1050
|
0.30
to 0.40
|
950
to 1050
|
0.3
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-56
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q013-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
nitrogen monoxide |
30
to 70
|
0.6
to 1.0
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G016
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
creatinine
|
creatinine |
98
to 100
|
0.1
to 0.6
|
98.7
to 98.8
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical measurements of DMR 180a, 263a
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-019
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
lindane (gamma-BHC) (gamma-HCH) |
12
to 900
|
3
to 1
|
3.1735
|
0.0410
|
Mechanism(s) for measurement service delivery:
DMR 277a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q021-011
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
n-tetradecane
|
n-tetradecane |
98
to 100
|
0.1
to 0.6
|
99.35
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-60
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-020
|