Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'Costa Rica' produced 80 results
|
New search
|
| | | Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas) | |  | Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
|  | |
| DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, > 0.1 mA to 1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31201 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 mA to 10 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31202 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 10 mA to 100 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 70 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31203 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 0.1 A to 1 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 97 to 167 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31204 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 A to 10 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 235 to 418 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31205 |
| | | DC current, DC current meters, low values. Multimeter, 0.01 mA to 0.1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 102 to 656 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32101 |
| | | DC current, DC current meters, intermediate values. Multimeter, > 0.1 mA to 1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 43 to 107 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32201 |
| | | DC current, DC current meters, intermediate values. Multimeter, 1 mA to 10 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 40 to 77 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32202 |
| | | DC current, DC current meters, intermediate values. Multimeter, 10 mA to 100 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 53 to 117 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32203 |
| | | DC current, DC current meters, intermediate values. Multimeter, 0.1 A to 1 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 94 to 204 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32204 |
| | | DC current, DC current meters, intermediate values. Multimeter, 1 A to 11 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 404 to 840 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32205 |
| | | AC voltage (up to the MHz range), AC voltage up to 1100 V, sources. Multifunction calibrator, source, oscilloscope calibrator, 0.01 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 72 to 31213 | | Direct comparison | | Frequency: 10 Hz to 500 kHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/52101 | | Uncertainty table |
| | | AC voltage (up to the MHz range), AC voltage up to 1100 V, meters. AC voltmeter, multimeter, multifunction calibrator, 0.01 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 50 to 10667 | | Direct comparison | | Frequency: 10 Hz to 1 MHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/52201 | | Uncertainty table |
| | | AC current, AC current up to 100 A, sources. Multifunction calibrator, source, 0.0001 A to 10 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 392 to 8803 | | Direct comparison | | Frequency: 10 Hz to 100 kHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/62101 | | Uncertainty table |
| | | AC current, AC current up to 100 A, meters. AC ammeter, multimeter, multifunction calibrator, 0.0001 A to 11 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 113 to 5849 | | Direct comparison | | Frequency: 10 Hz to 10 kHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/62201 | | Uncertainty table |
| | | AC power, AC power and energy, single phase (frequencies below or equal to 400 Hz). Watthour meter, wattmeter, 15 W to 12000 W | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 289 | | Comparison | | Frequency: 60 Hz | | Applied voltage: 120 V and 240 V | | Current: (0.25 A at 120 V and 0.3 A at 240 V) to 50 A | | Power factor: 1, 0.5 lead, 0.5 lag | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/71101 |
| | | Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia) | |  | Complete CMCs in Mass and related quantities for Costa Rica (.PDF file)
|  | |
| Conventional mass. Mass standards, 1 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 2 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 5 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 10 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
|