Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (6)
PHYSICS
Mass, mass standards (6)
Mass (6)
GEOGRAPHIC LOCATION
COOMET (6)
Belarus (6)
Result of the search
Your query 'belarus' produced 6 results New search

 
Belarus, BelGIM (Belarussian State Institute for Metrology)
Complete CMCs in Mass and related quantities for Belarus (.PDF file)
Mass. Mass standards, 1 mg to 100 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 2 to 4
Comparison in air
Air density: measured
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
Internal NMI service identifier: COO-M-BelGIM-1001
 
Mass. Mass standards, 0.1 g to 1 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 4 to 4.2
Comparison in air
Air density: measured
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
Internal NMI service identifier: COO-M-BelGIM-1002
 
Mass. Mass standards, 1 g to 10 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 4.2 to 6.5
Comparison in air
Air density: measured
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
Internal NMI service identifier: COO-M-BelGIM-1003
 
Mass. Mass standards, 10 g to 100 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 6.5 to 42
Comparison in air
Air density: measured
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
Internal NMI service identifier: COO-M-BelGIM-1004
 
Mass. Mass standards, 0.1 kg to 1 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 42 to 240
Comparison in air
Air density: measured
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
Internal NMI service identifier: COO-M-BelGIM-1005
 
Mass. Mass standards, 1 kg to 10 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.24 to 2.5
Comparison in air
Air density: measured
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
Internal NMI service identifier: COO-M-BelGIM-1005