Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (8)
PHYSICS
Dimensional metrology
Fluid flow (8)
Volume of liquid (8)
CHEMICAL ANALYTE
zinc
GEOGRAPHIC LOCATION
SIM (8)
Mexico (8)
Result of the search
Your query 'cenam' produced 8 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Mass and related quantities for Mexico (.PDF file)
Volume of liquid. Volumetric test measure (micro-pipette), 0.01 cm3 to 1 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV9
 
Volume of liquid. Volumetric test measure (pipette, burette, flask), 1 cm3 to 10 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.05
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV10
 
Volume of liquid. Volumetric test measure (pipette, burette, flask), 10 cm3 to 2000 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.01
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV11
 
Volume of liquid. Volumetric test measure (pycnometer), 10 cm3 to 100 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.004
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV12
 
Volume of liquid. Volumetric test measure (graduated neck type), 2 dm3 to 50 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.015
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV13
 
Volume of liquid. Volumetric test measure (overflow type pipette), 5 dm3 to 50 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.005
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV14
 
Volume of liquid. Volumetric test measure (graduated neck type), 50 dm3 to 3000 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.02
Volumetric transfer
Temperature: 18 °C to 26 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV15
 
Volume of liquid. Volume quantity meter, 50 dm3 to 3000 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.06
Turbine and positive displacement meter
Temperature: 18 °C to 26 °C
Kinematic viscosity: 0.5 mm2/s to 5 mm2/s
Flow: < 50 dm3/s
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV16