Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (86)
PHYSICS
DC voltage, current, and resistance (43)
Mass, mass standards (24)
Temperature (8)
Impedance up to the MHz range (6)
AC voltage, current, and power (5)
GEOGRAPHIC LOCATION
SIM (86)
Costa Rica (86)
Result of the search
Your query 'Costa Rica' produced 86 results New search
[<< Prev] 4  5

 
Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
AC current, AC current up to 100 A, meters. AC ammeter, multimeter, multifunction calibrator, 0.0001 A to 11 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 113 to 5849
Direct comparison
Frequency: 10 Hz to 10 kHz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/62201
Uncertainty table
 
AC power, AC power and energy, single phase (frequencies below or equal to 400 Hz). Watthour meter, wattmeter, 15 W to 12000 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 289
Comparison
Frequency: 60 Hz
Applied voltage: 120 V and 240 V
Current: (0.25 A at 120 V and 0.3 A at 240 V) to 50 A
Power factor: 1, 0.5 lead, 0.5 lag
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/71101
 
Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia)
Complete CMCs in Mass and related quantities for Costa Rica (.PDF file)
Conventional mass. Mass standards, 1 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 2 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 5 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 10 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 20 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 50 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.004
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 100 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.005
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 200 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.007
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 500 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.008
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 1 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.010
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 2 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.013
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 5 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.017
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 10 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.020
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 20 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.027
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 50 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.033
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 100 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.053
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 200 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.10
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 500 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.27
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01