Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (291)
CMCs General Physics (276)
PHYSICS >
Fluid flow
Force
Radio frequency measurements (52)
Mass, mass standards (28)
Sound in air (23)
Dimensional metrology (20)
Density (20)
Pressure (18)
Vibration (16)
Impedance up to the MHz range (16)
Torque, Viscosity, Hardness and Gravity (15)
AC voltage, current, and power (15)
Temperature (15)
Properties of detectors and sources (8)
CHEMICAL MATERIAL
HNO3 in aqueous solution (19)
aqueous pH buffer solution (6)
calcium carbonate (6)
clay (6)
ethanol-water 40% (9)
fresh water (8)
methanol (15)
monoelemental acidic (HNO3) aqueous solution (7)
nitrogen (12)
organic solution (14)
organic solution, multi-component (19)
particulates (15)
sediment (18)
soil (15)
synthetic natural gas (7)
CHEMICAL ANALYTE >
lead
acenaphthene
cadmium (8)
zinc (7)
chromium (5)
naphthalene (5)
nitrogen monoxide (5)
GEOGRAPHIC LOCATION
SIM (567)
Mexico (567)
Result of the search
Your query 'cenam' produced 567 results New search
[<< Prev] 29

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Photometry and Radiometry for Mexico (.PDF file)
Responsivity, laser, power. General detector. Measurand unit, A/W or V/W or Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.03
Laser source
Wavelength: 633 nm
Power level: 0.1 mW
Type of detector: Si trap
Si, ECPR detectors can be measured, uncertainty evaluated on each case
Internal NMI service identifier: CENAM/520-D007-001
 
Responsivity. Fibre optic power meter. Measurand unit, A/W or V/W or Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1.2
Comparison
Wavelengths: 850 nm, 1300 nm, 1550 nm
Bandwidth: 5 nm
Power level: 18 µW to 100 µW
Internal NMI service identifier: CENAM/520-D003-001, 002, 003, 004, 006
 
Responsivity, spectral, power. Broad band detector. Measurand unit, A/W, V/W, Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.8 to 0.62, varies with wavelength
Monochromator plus tungsten source
Wavelength range: 350 nm to 450 nm
Bandwidth: 4 nm
Power level: 0.4 µW to 4 µW
Internal NMI service identifier: CENAM/520-D007-001
 
Responsivity, spectral, power. Broad band detector. Measurand unit, A/W, V/W, Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.62 to 0.76, varies with wavelength
Monochromator plus tungsten source
Wavelength range: 450 nm to 770 nm
Bandwidth: 4 nm
Power level: 0.4 µW to 4 µW
Internal NMI service identifier: CENAM/520-D007-001
 
Responsivity, spectral, power. Broad band detector. Measurand unit, A/W, V/W, Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.76 to 1.5, varies with wavelength
Monochromator plus tungsten source
Wavelength range: 770 nm to 1100 nm
Bandwidth: 4 nm
Power level: 0.4 µW to 4 µW
Internal NMI service identifier: CENAM/520-D007-001
 
Irradiance, spectral. Tungsten lamp, 7.70E-03 (W/m2)/nm to 1.09E-01 (W/m2)/nm
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2.5
Spectroradiometer
Wavelength range: 400 nm to 795 nm
Bandwidth: 2.5 nm
Internal NMI service identifier: CENAM/520-D005-007
 
Irradiance, spectral. Tungsten lamp, 1.11E-01 (W/m2)/nm to 1.13E-01 (W/m2)/nm
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 4
Spectroradiometer
Wavelength range: 800 nm to 995 nm
Bandwidth: 2.5 nm
Internal NMI service identifier: CENAM/520-D005-007