Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'Costa Rica' produced 86 results
|
New search
|
| | | Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas) | |  | Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
|  | |
| DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, > 0.1 mA to 1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31201 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 mA to 10 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31202 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 10 mA to 100 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 70 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31203 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 0.1 A to 1 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 97 to 167 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31204 |
| | | DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 A to 10 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 235 to 418 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31205 |
| | | DC current, DC current meters, low values. Multimeter, 0.01 mA to 0.1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 102 to 656 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32101 |
| | | DC current, DC current meters, intermediate values. Multimeter, > 0.1 mA to 1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 43 to 107 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32201 |
| | | DC current, DC current meters, intermediate values. Multimeter, 1 mA to 10 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 40 to 77 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32202 |
| | | DC current, DC current meters, intermediate values. Multimeter, 10 mA to 100 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 53 to 117 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32203 |
| | | DC current, DC current meters, intermediate values. Multimeter, 0.1 A to 1 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 94 to 204 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32204 |
| | | DC current, DC current meters, intermediate values. Multimeter, 1 A to 11 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 404 to 840 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/32205 |
| | | Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors. Fixed capacitor, capacitance box, 10 pF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 5.0E-04 | | Substitution | | Frequency: 1000 Hz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/42201 |
| | | Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors. Fixed capacitor, capacitance box, 100 pF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 2.0E-04 | | Substitution | | Frequency: 1000 Hz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/42202 |
| | | Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors. Fixed capacitor, capacitance box, 1000 pF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 7.5E-05 | | Substitution | | Frequency: 1000 Hz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/42203 |
| | | Impedance (up to the MHz range), capacitance, meters. Capacitance meter, LCR meter, 10 pF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 5.0E-04 | | Direct comparison | | Frequency: 1000 Hz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/42401 |
| | | Impedance (up to the MHz range), capacitance, meters. Capacitance meter, LCR meter, 100 pF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 2.0E-04 | | Direct comparison | | Frequency: 1000 Hz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/42402 |
| | | Impedance (up to the MHz range), capacitance, meters. Capacitance meter, LCR meter, 1000 pF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 7.5E-05 | | Direct comparison | | Frequency: 1000 Hz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/42403 |
| | | AC voltage (up to the MHz range), AC voltage up to 1100 V, sources. Multifunction calibrator, source, oscilloscope calibrator, 0.01 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 72 to 31213 | | Direct comparison | | Frequency: 10 Hz to 500 kHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/52101 | | Uncertainty table |
| | | AC voltage (up to the MHz range), AC voltage up to 1100 V, meters. AC voltmeter, multimeter, multifunction calibrator, 0.01 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 50 to 10667 | | Direct comparison | | Frequency: 10 Hz to 1 MHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/52201 | | Uncertainty table |
| | | AC current, AC current up to 100 A, sources. Multifunction calibrator, source, 0.0001 A to 10 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 392 to 8803 | | Direct comparison | | Frequency: 10 Hz to 100 kHz | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/62101 | | Uncertainty table |
|