Search facility:  
BIPM Home | Site map | Metrologia | KCDB | JCTLM-DB | Contact us  
   
Calibration and measurement services: Ionizing radiation
Traceability to the SI through the BIPM
Subject area:
What is traceability?
BIPM policy on stating uncertainties
Summary
BIPM services in the field of electricity
BIPM services in the field of ionizing radiation
BIPM calibrations and services in mass and related quantities
BIPM services in the field of time, frequency and gravimetry
Related articles
Calibration certificates issued by the Ionizing Radiation Department
KCDB
Direct access

BIPM Ionizing Radiation Department
Complete list of uncertainties for services offered to NMIs by the BIPM in Ionizing Radiation (.PDF file)
Absorbed dose-rate to water. National standard ionization chamber, 1E-03 Gy s–1 to 10E-03 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.6
Source: Co-60
Calibration against a primary standard in a water phantom
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1001

Air kerma-rate. National standard ionization chamber, 1E-03 Gy s–1 to 10E-03 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.3
Source: Co-60
Calibration against a primary standard free in air
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1002

Air kerma-rate. National standard ionization chamber, 5E-04 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.4
X-ray: 100 kV to 250 kV
Calibration against a primary standard free in air
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1003

Air kerma-rate. National standard ionization chamber, 1E-03 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.4
X-ray: 10 kV to 50 kV
Calibration against a primary standard free in air
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1004

Air kerma-rate. National standard ionization chamber, 2E-03 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.4
X-ray: 23 kV to 50 kV (Mammography beams)
Calibration against a primary standard free in air
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1004M

Air kerma-rate. National standard ionization chamber, 2E-05 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.4
Source: Cs-137
Calibration against a primary standard free in air
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1005

Air kerma-rate. National standard ionization chamber, 7E-06 Gy s–1 to 8E-06 Gy s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.3
Source: Co-60
Calibration against a primary standard free in air
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1006

Ambient dose equivalent-rate. National standard ionization chamber, 2E-06 Sv s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 1.0
Source: Cs-137
Calibration against a primary standard in an ICRU spherical phantom
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1007

Ambient dose equivalent-rate. National standard ionization chamber, 8E-07 Sv s–1 to 9E-07 Sv s–1
Relative expanded uncertainty (k = 2, level of confidence approximately 95%) in %: 0.6
Source: Co-60
Calibration against a primary standard in an ICRU spherical phantom
BIPM primary standard under CCRI reference conditions, Rapport BIPM-2011/04
Service identifier: BIPM-RAD-1008



Related articles